A wirelessly powered implant that delivers electrical stimulation helps remove excess glucose from the bloodstream and promote the use of stored fat without administering drugs, as shown in an experimental study.
Developed by researchers from the ETH Zurich in Basel, Switzerland, the ECHO (electrocatalytic closed-loop health optimization) device features a wirelessly powered electrocatalytic implant that oxidizes excess glucose to gluconate for renal clearance.
“The device [is paired with a continuous glucose monitoring (CGM) device] and operates in a closed loop to detect hyperglycaemia and trigger on-demand electrocatalysis,” said lead researcher Prof Martin Fussenegger.
“When CGM readings exceed a preset threshold, the smartphone initiates wireless power transfer to the ECHO device, where the catalyst oxidizes glucose to gluconate. This reduces circulating glucose and creates a controlled caloric sink, shifting substrate utilization toward lipid catabolism,” Fussenegger explained.
“Under normoglycemia, the wireless controller deactivates stimulation to maintain homeostatic glucose levels,” he added.
Fussenegger and colleagues tested the closed-loop system in mouse models of T2D. After implantation of the ECHO device, elevated blood glucose levels rapidly fell within the normal range. Glucose control was maintained over the 6-week treatment period without any detectable hypoglycaemic events. [Science 2026;doi:10.1126/science.ady8560]
Consequently, there was a shift from glucose-based to fat-based energy metabolism. Mice who received the ECHO device implant lost up to 10 percent of their body weight and showed reduced circulating triglyceride concentrations and increased free fatty acid and ketone body concentrations.
The implanted device remained functional throughout the treatment period, and there were no documented adverse physiological, inflammatory, or behavioural effects, according to Fussenegger.
“The system operates at a very low voltage, and our experiments showed no evidence of tissue damage from either electrical or thermal effects,” he added.
Fussenegger, along with his colleagues, believed that closed-loop electrocatalytic devices offer a potential route toward drug-sparing, dynamically controlled metabolic interventions.
“This drug-free mode of action is relevant because current pharmacological therapies for diabesity can be limited by adverse effects, tolerability, adherence, cost, and unresolved long-term safety questions,” the researchers said.
“The electrocatalytic ECHO device can seamlessly integrate with modern electronics and can in principle connect to a variety of wearable devices, smartphones, and cloud-based Internet-of-Things networks. This enables real-time monitoring, online diagnostics, and therapeutic interventions, by either the patient or medical professionals, or through artificial intelligence–driven algorithms that anticipate daily routines and lifestyle changes,” they added.
The next step in the research is to determine whether the device can facilitate glucose clearance under perfusion conditions matching human blood volumes, Fussenegger said.